ZOLL CPR-D Training Padz (8900-0804-01)

Inc.VAT £127.20 £106.00
FREE Delivery
Current Lead Time Call 01298 872 186 for latest delivery times
91 100 40

The ZOLL CPR-D Training Padz are reusable training electrodes designed for use with the ZOLL AED Plus Trainer 2. They replicate the physical form and application method of the clinical CPR-D Padz used with the ZOLL AED Plus, allowing training participants to practise correct electrode placement without consuming clinical-grade consumables.

The electrode uses ZOLL's Z-design. A one-piece construction that positions both pads across the chest in a single application motion. Clear anatomical images and a CPR hand placement indicator are printed on the electrode surface, guiding correct pad positioning and reinforcing hand placement during chest compression practice.

An adjustable toggle allows the electrode to be repositioned on the chest to accommodate patients with a larger frame, ensuring accurate placement training across a range of body types.

Compatible with: ZOLL AED Plus Trainer 2 only. These are training electrodes. They cannot be connected to a clinical AED device or used on a patient.

Note: The gel pads must be attached to the electrode before use. They are reusable across multiple training sessions, replace them when adhesion weakens or the pads become soiled. Additional replacement gel pad sets are available separately.

What's Included

  • 1 × Reusable CPR-D Padz electrode (Z-design, one-piece adult)

For more information, please contact us on 01298 872 186 or use the web chat to speak with one of our specialists.

Who Uses These Pads?

The ZOLL CPR-D Training Padz are purchased primarily by:

  • Training coordinators running AED sessions with the ZOLL AED Plus Trainer 2; these pads allow repeated, realistic electrode placement practice without replacing clinical consumables.

  • Health and safety managers maintaining workplace AED competency programmes under HSE guidelines, where regular refresher training is required.
  • HR departments responsible for first aid and emergency response readiness, particularly in organisations with ZOLL AED Plus devices deployed on site.
  • Training organisations delivering accredited CPR/AED courses who need durable, reusable training consumables that mirror the clinical product their students will encounter in the field.

Technical Specifications 

Part number 8900-0804-01
Compatible device ZOLL AED Plus Trainer 2 only
Electrode type Training (not for clinical use)
Design Z-design, one-piece, adult
Gel pads included 1 pair (disposable, single-use)
Electrode Reusable
Approval MDR (UK), CE
Sold as Single unit

Compatibility Note

These pads are compatible with the ZOLL AED Plus Trainer 2 (part no. 8008-0050-01) only. They are not compatible with the standard ZOLL AED Plus clinical device and must not be used in a real emergency situation. The CPR compression feedback sensor included in the clinical CPR-D Padz does not function in the training electrode; this is expected behaviour; feedback during training is provided by the Trainer 2 unit itself.

If you need replacement pads for a clinical ZOLL AED Plus, see the ZOLL CPR-D Padz page.

Frequently Asked Questions 

Are these training pads compatible with the standard ZOLL AED Plus (live device)?

No. The ZOLL CPR-D Training Padz (8900-0804-01) are designed exclusively for use with the ZOLL AED Plus Trainer 2. They cannot be connected to a clinical ZOLL AED Plus device. If you need replacement electrodes for a clinical AED Plus, please see our ZOLL CPR-D Padz page.

Are these pads reusable?

Yes, both the electrode assembly and the gel pads are reusable. The gel pads can be used across multiple training sessions and should be replaced when adhesion weakens or the pads become soiled. Additional gel pad sets are available separately.

Can I buy replacement gel pads separately?

Yes. If you already have the reusable electrode assembly, replacement adhesive gel pads are available separately.

Will the CPR depth feedback sensor work on these training pads?

No. The CPR compression feedback sensor built into the clinical CPR-D Padz does not function on the training electrode. This is by design, CPR feedback during training is provided by the ZOLL AED Plus Trainer 2 unit itself, not the training electrode.

How many times can the training electrode be reused?

ZOLL does not publish a defined number of reuse cycles for the electrode assembly. The electrode can be reused indefinitely provided it is in good condition, and the gel pads are replaced before each session. Inspect the electrode before each training session and replace it if the casing, cable, or connector shows signs of damage.

What is the 'Z-design' and why does it matter?

The Z-design is ZOLL's one-piece electrode shape, which allows both pads to be applied to the patient's chest in a single continuous motion. Training with the Z-design ensures that participants develop the correct technique and muscle memory for the actual CPR-D Padz they would use in a real emergency, reducing hesitation at the critical moment of deployment.

More Information
Brand Zoll